Flush Door Skin Doors
VELVA FLUSH Doors
Velva Pine Wood Flush Door is a quality product from the house of Vaishnavi laminates and wood work. It is manufactured in accordance with IS 2202, and made from highly fibrous pinewood and selected core veneers. The layers are bonded with phenolformaldehyde resin and glue line protector. We use in house made resin manufactured as per IS- 848: 2006 standards, using high-tech manufacturing facilities. The quality to produce sturdy & longlasting door.
KEY FEATURES:
- Conditioned doors Warp and twist resistant.
- 100% boiling water proof
- High load bearing capacity
- Extra lock rail for fittings
- Smooth surface for lamination of MICA or veneer.
- Imported Sylvester Pinewood used in the manufacturing of stiles and rails.
- Hydroxybenzene based adhesives and high quality preservatives to provide borer and termite resistance.
Technical Specifications:
S.No. |
TEST |
ISI REQUIREMENT |
Observed Value |
---|---|---|---|
01. | Dimension | Length, Width - + 5 mm Thickness - + 1 mm | Within limits |
02. | Squareness | Deviation not more than 1 mm on a length of 500mm | Deviation below 1 mm |
03. | General Flatness | Twist, cupping, warping not to exceed 6 mm | |
04. | Local Planeness | Depth of deviation at any point to be less than 0.5 mm | Within limits |
05. | Impact Indentation Test | Depth of Indentation not to exceed 0.2 mm | Within limits |
06. | Edge Loading Test | Deflection of edge with max. To be less than 5 mm | Within limits |
07. | Shock Resistance Test | No visible defect after test | No visible defects |
08. | Buckling Test | Initial deflection - < 50 mm residual deflection - < 5 mm | Within limits |
09. | Slamming Test | No visible damage after Test | No visible damage |
10. | Misuse Test | No deformation after Test | No deformation |
11. | Varying Humidity Test | No visible warping, twisting or de-lamination | No such defects observed |
12. | End Immersion Test | No de-lemination at the end | No de-lemination |
13. | Knife Test | Minimum Pass Standard | Excellent |
14. | Glue Adhesion Test | No de-lamination | No de-lamination |
15. | Screw Withdraw Test | Load to withdraw screw to be more than 1000 N | Load - > 1000 N |